Each module consists of 1 receive/1 transmit channel as shown in the diagram. The module must be equipped with power fault status reporting, temperature detection reporting, lockout indication reporting, etc.
No. | Parameters | Symbols | Limit values | Unit | Remarks | ||
Min. value | Max. value | ||||||
1 | Emission parameters | Input Frequency | 1.3 | 2.3 | GHz | ||
2 | Output Frequency | 6 | 18 | GHz | |||
3 | Input Power | -11 | -9 | dBm | |||
4 | Transmitting Power | -3 | 3 | dBm | Single Channel | ||
5 | If Branch Attenuation | 55 | dB | ||||
6 | Modulation Switch On/Off Ratio | 60 | dB | ||||
7 | Harmonic Suppression | 15 | dBc | 6~10GHz | |||
8 | Harmonic Suppression | 35 | dBc | 10~18GHz | |||
9 | Stray | 40 | dBc | ||||
10 | Standing Waves | 2 | |||||
11 | Stray Suppression | 40 | - | dBc | |||
12 | Total Power Consumption | - | 40 | W | With acceptance | ||
13 | Receiving parameters | Input Frequency | 6 | 18 | GHz | ||
14 | Local Vibration Switching | 200 | ns | ||||
15 | Instantaneous Bandwidth | 1 | GHz | ||||
16 | Input Dynamics | -65 | 30 | dBm | |||
17 | Noise Factor | NF | - | 7 | dB | Full temperature | |
18 | Input Anti-Burn-In | 10 | - | W | |||
19 | Stray Suppression | 40 | dBc |