Each module consists of 3 receive/transmit channels and 2 frequency channels, each of which is connected to the antenna at the RF end. The module must be equipped with power fault status reporting, temperature detection reporting, and load status reporting within the module.
Electrical performance table(TA = +25°C)
No. | Parameters | Min. value | Max. value | Unit | ||
1 | Launch Parameters | Channel Gain | 1 | 45 | dB | |
2 | Transmitting power | 33 | - | dBm | ||
3 | Third order intermodulation | - | -35 | dBc | ||
4 | Two-way IF Range imbalance degree | -0.5 | 0.5 | dB | ||
5 | Range Consistency | -1 | 1 | dB | ||
6 | Phase Consistency | -15 | 15 | ° | ||
7 | Additional attenuation by phase shift | -0.8 | 0.8 | dB | ||
8 | Phase shift error | - | 5 | ° | ||
9 | Attenuated additional phase shift | -5 | 5 | ° | ||
10 | Attenuation error | - | 0.8 | dB | ||
11 | Stray Inhibition | With inner | -6 | - | dBc | |
12 | With external | -40 | - | dBc | ||
13 | Shutdown Depth | -60 | - | dBc | ||
14 | Launch Shutdown Output Noise Power Density | 14 | dBm/Hz | |||
- | ||||||
15 | Total Power Consumption | - | 38 | W | ||
16 | Receiving Parameters | Channel Gain | 3 | 37 | dB | |
17 | 0 | -20 | dB | |||
18 | Noise Factor | - | 3.5 | dB | ||
19 | Input Anti-Burn-In | 1 | - | W | ||
20 | Input 1 dB Compression Point | -35 | - | Bm | ||
21 | 0 | 20 | dBm | |||
22 | Third Order Intermodulation | - | -40 | dBc | ||
23 | - | -40 | dBc | |||
24 | Two-way IF Range imbalance degree | -0.5 | 0.5 | dB | ||
25 | Range Consistency | -1 | 1 | dB | ||
26 | Phase Consistency | -15 | 15 | ° | ||
27 | Additional attenuation by phase shift | -0.8 | 0.8 | dB | ||
28 | Phase shift error | - | 5 | ° | ||
29 | Attenuated additional phase shift | -5 | 5 | ° | ||
30 | Attenuation error | - | 0.8 | dB | ||
31 | Mirror Suppression | - | - | dBc | ||
32 | Stray Inhibition | With inner | -5 | - | dBc | |
33 | With external | -60 | - | dBc |