C-Band Microwave Combination

prod-banner
Product Classification

C-Band Microwave Combination

share:

Each module consists of 1 receive/1 transmit channel as shown in the diagram. The module must be equipped with power fault status reporting, temperature detection reporting, lockout indication reporting, etc.

No.ParametersTest indexUnit
1Base frequency signal FS1Signal frequency240MHz
2Signal power2 ~ 5dBmW
3Stray level≤-70dBc
4Phase noise≤-110dBc/Hz@1kHz
5Harmonic level≤-40dBc
6Base frequency signal FC1Signal frequency2880MHzMHz
7Signal power2 ~ 5dBmW
8Spurious level≤-70dBc
9Phase noise≤-102dBc/Hz@1kHz
10Harmonic level≤-40dBc
11Medium frequency
excitation signal TF1
Signal frequency5.56 (low and medium
frequency channels)
GHz
12Signal power11 ~ 14dBmW
13Spurious level≤-70dBc
14Modulation depthGreater than 70dB
15Receive channel output
signals DY2, DZ2, S2
Center Frequency300MHz
16Signal bandwidth80 and 5MHz
17Signal Power(peak)<10dBmW
18Total receive channel gain65 ~ 71dB
19Receiving channel noise factor<8.5 (Small signal)dB
20Isolation between receiving channels>40dB
21Receiving channel mirror frequency suppression system>20dB


Inquire Now